Hickenbottom,
Inc.
Inlet Intake
General
Information for Installation Practices
Installation for all Hickenbottoms Inlets should be in
accordance with specs. For corrugated P.E. piping, such as ASTM F-405 and
In
general terms of back filling the inlet, we would recommend at very shallow
depths of less than 24 to bed tee and under ground portion of inlet with an
aggregate of ½ up to 1 ½ stone or (limey chips). In all normal conditions of depths over 24
and up to 72 of depth, the spoil from the trench can be used if the size of
material is smaller then 2 in diameter.
It is moist and pliable so as to be able to compact the soil properly
around the pipe.
In
conditions deeper than 72, the inlet should be back filled with the above-described
aggregate and should be filled around the vertical portion of the inlet with
approximately 12 of aggregate around the pipe to the surface.
To
help alleviate the problem of the vertical portion of the inlet being tipped
over during the back filling process, we recommend filling around the inlet and
tamping soil in a mounding fashion then tapering the slope down away from the
inlet to the bottom of the trench.
If
you have any further questions about installation, please call the general
office at 800-443-7879.












Hickenbottom,
Inc.
Inlet Intake

5 Intake
Description and Use
1. The (intake bell) fits inside SDR.35-6 spigot, fairly well.
2. 5 (tile bell) fits over 4 bell end of SDR.26 and SDR.21 and Sch 40, fair to loose.
3. 5 (tile bell) fits inside 6 bell end of SDR. 35 very well.
4. 5 (tile bell) fits on 5 spigot end of Sch 40, SDR.21 and SDR.26 fairly well.
5. 5 (intake bell) will fit 5 Fernco plastic adapter.
6. 5 (tile bell) will fit 6 Fernco plastic adapter.
7. You can use a Hancor 5x4 reducer which will snap directly into (tile bell) end of tee and snap over 4 tile to be used. Product #FC-R04-05
8. You can use an A.D.S. 5x4 external reducer but will have to use a piece of 5 tile to connect the reducer and tee. Product #0514AA
9. You can use a Hickenbottom 5x4 reducer but will also need a piece of 5 tile to connect the reducer to the tee. Product #HBI-504
10. PCX 56-64 (Fernco) will fit over bell of tee and connect it to 4 PVC pipe.
We have all the
adapters described above available for your convenience.
1. 5 stack bell or spigot end will fit 5 Fernco plastic adapter fairly well.
2. You can use a 5 Internal Coupler in the spigot end of stack to connect to 5 tile or to repair an existing 5 intake. (Also a A.D.S. 6x5 internal reducer will work to connect to 6 field tile.) Product #0526AA
Please refer to CFS chart for further flow capacities.
HBI-5510 Section contains 24 each 1 holes per foot and is used in standard conditions with 4 and 5 and sometimes 6 tile where the flow of a 6 intake is not needed. (Refer to CFS chart for flow capacities and tile drainage chart or contact your local Soil Conservation Office.)
HBI-5121 Section is the same as HBI-5510 but in ½ section.
HBI-55SL A 5 x 1 holed section with 3 each 1 x 4 slots per foot. It is used to provide more flow than a 5 x 1 section can provide and where a 6 x 1 section is too much. It can also be used in conjunction with a 5 restrictor to help eliminate trash build up due to possible restriction of the 1 holes.
HBI-5FSL A 5 x 1 holed section with the top half fully slotted. This was designed to provide maximum flow for the upper half of the inlet without having to use a wire trash rack or Bar Guard. The lower half has 1 holes to provide the standard flow release for remaining water in the terrace.
HBI-5516 A 5 x 5/16 holed orange section used underground from the tee as a riser extension. It can be cut at different locations (as marked on the section) to adjust the height of the intake.
HBI-5125 Section is the same as the HBI-5516 but in ½ section.
5 Intake Part Description continued
HBI-55BL Section is a standard blank section, currently made in the color orange, and is blind on both ends. It can also be used in place of HBI-5516 where no small holes are wanted below ground. This can only be used in the vertical position.
HBI-512B Section is the same as the above but in half section.
HBI-5BTS A 5 short tee. Excepts a 5 field tile into the bell only or a 5 x 4 reducer.
HBI-5440 A 5 x 4 reducer used to adapt the 5 intake tee so it an be connected to the 4 corrugated tile. It will take a small length of 5 corrugated tile to connect the tee to the reducer.
HBI-50R0 A 5 restrictor used to adjust the flow of water from the intake to the main line. Contact your local SCS office for proper hole size in the restrictor.
HBI-5SBO A 5 x 1 section with the bottom left blind which can act as a built in restrictor. Removing the section and changing restrictor hole size with a saw can easily change it.
6 Intake
Description and Use
1. 6 (tile bell) fits over 6 SDR.35 bell a little sloppy.
2. 6 (tile bell) fits over 6 DR.-C900 spigot very good.
3. You can use our Product #HBI-654 reducer to connect 6 intake tee to 6 field tile. The reducer will fit directly into the bell of our tee.
4. You can also use Hancors 6 x 5 reducer, Product #FC-R05-06, or their 6 x 4 reducer Product #FC-R04-06, both will fit directly into our intake tee bell.
5. You can use most other 6 reducers made but may have to use a piece of 6 field tile to connect the tee to the tile.
1. The spigot of the 6 stack will fit all 6 SDR.35 bell end fittings.
2. The 6 stack bell will fit inside the 6 Schedule 40 bell but you will have to cut off the bell below the rib on the bell in order to get the 6 Schedule 40 bell to go over the 6 stack bell.
3. The 6 stack spigot fits the Fernco plastic adapter.
Please refer to CFS chart for further flow capacities.
HBI-6610 Section contains 40 each 1 holes per foot and is used in standard conditions with 4, 5 and 6 tile and sometimes 8 where the flow of an 8 intake is not needed. (Refer to the CFS chart for flow capacities and tile drainage chart or contact your local Soil Conservation Office.)
HBI-6121 Section is the same as HBI-6610 but in ½ section.
HBI-66SL A 6 x 1 holed section with 5 each 1 x 4 slots per foot. It is used to provide more flow than a 6 x 1 section can provide and where an 8 x 1 section is to much. It can also be used in conjunction with a 6 restrictor to help eliminate trash buildup due to possible restriction of the 1 holes.
HBI-6FSL A 6 x 1 holed section with the top half fully slotted. This was designed to provide maximum flow for the upper half of the inlet with out having to use a wire trash rack or Bar Guard. The lower half has 1 holes to provide the standard flow release for remaining water in the terrace.
HBI-6516 A 6 x 5/16 holed orange section used underground from the tee as a riser extension. It can be cut at different locations (as marked on the section) to adjust the height of the intake.
HBI-6125 Section is the same as HBI-6516 piece but in ½ section.
HBI-66BL Section is a standard blank section, currently made in the color orange, and is blind on both ends. It can also be used in place of HBI-6516 where no small holes are wanted below ground. It can only be used in the vertical position.
HBI-612B Section is the same as HBI-66BL but in ½ section.
6 Intake Part Description continued
HBI-6BTN A 6 blind tee that will connect directly to a 6 corrugated tile by inserting the tile into the tile bell of the tee.
HBI-65BT A 6 x 5 New Style tee to be used to connect directly to 6 corrugated tile and has a 5 inlet bell so that a 5 intake section can be snapped directly into the tee with out the use of an adapter.
HBI-6540 Used to connect a 6 New Style tee (HBI-6BTNS) to 4 corrugated tile. It inserts directly into the tile bell of the reducer. It can be cut off to fit 5 corrugated tile also. This makes this reducer completely universal as a 6 x 5 reducer and a 6 x 4 reducer.
HBI-6550 Used to connect a 6 New Style tee (HBI-6BTNS) to 5 corrugated tile. It inserts directly into the tile bell of the New Style tee and the 5 corrugated tile inserts into the bell of the reducer.
HBI-60R0 A 6 restrictor used to adjust the flow of water from the intake to the main line. Contact your local SCS office for proper hole size in the restrictor.
HBI-6SBO A 6 x 1 section with the bottom left blind which can act as a built in restrictor. Removing the section and changing restrictor hole size with a saw can easily change it.
HBI-66BLN Section is an approximate 3 of dual wall, currently made in the color black, and is open on both ends. Standard use is to offset the intake from the main line.
8 Intake
Description and Use
1. The 8 intake tee bell fits the bell of the 8 SDR.35 loosely, but would work if necessary.
6. The tee bell fits over the bell of the 8 Schedule 40 fairly tight.
7. The 8 tee bell fits inside of a #1056-1010, plastic to plastic, Fernco coupler.
1. The spigot of the 8 stack will fit all bells of 8 Schedule 40, SDR.21 and SDR.26.
2. The spigot of the 8 stack will fit inside of the Fernco 8 plastic adapter.
Please refer to CFS chart for further flow capacities.
HBI-8810 Section contains 56 each 1 holes per foot and is used in standard conditions where an 8 intake is needed for capacity. (Refer to the CFS chart for flow capacities and tile drainage chart or contact your local Soil Conservation Office.)
HBI-8121 Section is the same as HBI-8810 but in ½ section of approximately 19 length.
HBI-88SL An 8 x 1 holed section with 8 each 1 x 4 slots per foot. It is used to provide more flow than a 8 x 1 section can provide and where an 10 x 1 section is to much. It can also be used in conjunction with a 6 restrictor to help eliminate trash buildup due to possible restriction of the 1 holes.
HBI-8FSL A 8 x 1 holed section with the top half fully slotted. This was designed to provide maximum flow for the upper half of the inlet with out having to use a wire trash rack or Bar Guard. The lower half has 1 holes to provide the standard flow release for remaining water in the terrace.
HBI-8516 A 8 x 5/16 holed orange section used underground from the tee as a riser extension. It can be cut at different locations (as marked on the section) to adjust the height of the intake.
HBI-8125 Section is the same as HBI-8516 piece but in ½ section of approximately 19 length.
HBI-88BL Section is a standard blank section, currently made in the color orange, and is blind on both ends. It can also be used in place of HBI-8516 where no small holes are wanted below ground. It can only be used in the vertical position.
HBI-812B Section is the same as HBI-88BL but in ½ section of approximately 19 length.
8 Intake Description and Use continued
HBI-8BTN An 8 (New Style Tee) which can be connected directly to 8 corrugated tile or dual wall.
HBI-80R0 An 8 restrictor used to adjust the flow of water from the intake to the main line. Contact your local SCS office for proper hole size in the restrictor.
HBI-888Y Section is 8 x 8 x 8. Two ends are blind and are marked for different sizes of corrugated tile.
HBI-8SBO A 8 x 1 section with the bottom left blind which can act as a built in restrictor. Removing the section and changing restrictor hole size with a saw can easily change it.
HBI-88BLN Section is an approximate 3 of dual wall, currently made in the color black, and is open on both ends. Standard use is to offset the intake from the main line.
10 Intake
Description and Use
1. The 10 intake tee bell fits tight over SDR.35 10 belled end.
2. The 10 intake tee bell fits tight on the bell of Schedule 40 10.
3. The 10 tee bell fits inside of a #1056-1212, plastic to plastic, Fernco coupler.
1. The 10 intake stack bell will fit over 10 SDR.35 spigot and 10 Schedule 40, SDR.21 and SDR.26 spigots fairly well.
Please refer to CFS chart for further flow capacities.
HBI-1010 Section contains 72 each 1 holes per foot and is used in standard conditions where a 10 intake is needed for capacity. (Refer to the CFS chart for flow capacities and tile drainage chart or contact your local Soil Conservation Office.)
HBI-10121 Section is the same as HBI-1010 but in ½ section of approximately 19 length.
HBI-10SL A 10 x 1 holed section with 8 each 1 x 4 slots per foot. It is used to provide more flow than a 10 x 1 section can provide and where a 12 x 1 section is too much. It can also be used in conjunction with a 10 restrictor to help eliminate trash buildup due to possible restriction of the 1 holes.
HBI-10FSL A 10 x 1 holed section with the top half fully slotted. This was designed to provide maximum flow for the upper half of the inlet with out having to use a wire trash rack or Bar Guard. The lower half has 1 holes to provide the standard flow release for remaining water in the terrace.
HBI-10516 A 10 x 5/16 holed orange section used underground from the tee as a riser extension. It can be cut at different locations (as marked on the section) to adjust the height of the intake.
HBI-10125 Section is the same as HBI-10516 piece but in ½ section of approximately 19 length.
HBI-10BL Section is a standard blank section, currently made in the color orange, and is blind on both ends. It can also be used in place of HBI-10516 where no small holes are wanted below ground. It can only be used in the vertical position.
HBI-1012B Section is the same as HBI-10BL but in ½ section of approximately 19 length.
10 Intake Description and Use continued
HBI-10BTN A 10 (New Style Tee) which can be connected directly to 10 corrugated tile or dual wall.
HBI-10R0 A 10 restrictor
used to adjust the flow of water from the intake to the main line. Contact your local SCS office for proper hole
size in the restrictor. This part is currently built in on the
HBI-1010. This part is custom made for
any other piece at this time.
HBI-10SBO A 10 x 1 section with the bottom left blind which can act as a built in restrictor. Removing the section and changing restrictor hole size with a saw can easily change it.
HBI-10BLN Section is an approximate 3 of dual wall and is open on both ends. Standard use is to offset the intake from the main line.
12 Intake
Description and Use
Please refer to CFS chart for further flow capacities.
HBI-1210 Section contains 72 each 1 holes per foot and is used in standard conditions with 12 tile where a 12 x 1 flow rate is needed. This unit can also be fitted with 72 each 1 Ό holes or 72 each 1 ½ holes or 72 each 1 ½ holes. These are special size holes and must be requested. There will be an added charge for these size changes. (Refer to the CFS chart for flow capacities and tile drainage chart or contact your local Soil Conservation Office.)
HBI-12121 Section is the same as HBI-1210 but in ½ section of approximately 44 length.
HBI-12SL A 12 x 1 holed section with 12 each 1 x 4 slots per foot. It is used to provide more flow than a 12 x 1 section can provide and where a 15 x 1 section is too much. It can also be used in conjunction with a 12 restrictor to help eliminate trash buildup due to possible restriction of the 1 holes.
HBI-12FSL A 12 x 1 holed section with the top half fully slotted. This was designed to provide maximum flow for the upper half of the inlet with out having to use a wire trash rack or Bar Guard. The lower half has 1 holes to provide the standard flow release for remaining water in the terrace.
HBI-12516 A 12 x 5/16 holed orange section used underground from the tee as a riser extension. It can be cut at different locations (as marked on the section) to adjust the height of the intake.
HBI-12125 Section is the same as HBI-12516 piece but in ½ section of approximately 21 length.
HBI-12BL Section is a standard blank section, currently made in the color orange, and is blind on both ends. It can also be used in place of HBI-12516 where no small holes are wanted below ground. It can only be used in the vertical position.
HBI-1212B Section is the same
as HBI-12BL but in ½ section of approximately 21 length.
12 Intake Description and Use continued
HBI-12BT A 12 tee designed to connect directly to 12 corrugated tile or dual wall.
HBI-12R0 A 12 restrictor
used to adjust the flow of water from the intake to the main line. Contact your local SCS office for proper hole
size in the restrictor. This part is
currently built in on the HBI-1210. This
part is custom made for any other piece at this time.
HBI-12SBO A 12 x 1 section with the bottom left blind which can act as a built in restrictor. Removing the section and changing restrictor hole size with a saw can easily change it.
HBI-12BLN Section
is an approximate 3 of dual wall and is open on both ends. Standard use is to
offset the intake from the main line.
Hickenbottom,
Inc.
Inlet Intake